MBE 900 DDEC VI Troubleshooting – Section 5.11 Aerated Fuel

Section 5.11
Aerated Fuel

To determine if aerated fuel is causing starting difficulty, perform the following steps:‪

  1. Disconnect the fuel line return hose from the fitting located at the fuel tank; refer to OEM guidelines.
  2. Place the opened end of the fuel line into a suitable container.
    warning

    PERSONAL INJURY

    To avoid injury before starting and running the engine, ensure the vehicle is parked on a level surface, parking brake is set, and the wheels are blocked.‪

  3. Start the engine.
  4. Run the engine at 1000 rpm.
  5. Visually check to see if air bubbles are rising to the surface of the fuel within the container.
    1. If air bubbles are present, repair is necessary; refer to "5.11.1 Aerated Fuel Resolution" .
    2. If air bubbles are not present, check for a restrictive air filter. Shut down the engine; refer to "5.12 Restrictive Air Filter" .

Section 5.11.1
Aerated Fuel Resolution

Perform the following steps for aerated fuel resolution:‪

  1. Shut down the engine.
  2. Tighten all fuel line connections between fuel tank and fuel pump; refer to OEM guidelines.
  3. Visually inspect all fuel lines between fuel tank and fuel pump for leaks.
  4. Replace damaged components as required; refer to OEM guidelines.
  5. Verify aerated fuel resolution; refer to "5.11.1.1 Test Engine with Aerated Fuel Resolution" .
Section 5.11.1.1
Test Engine with Aerated Fuel Resolution

To determine if aerated fuel resolution resolved starting difficulty, perform the following steps:‪

warning

PERSONAL INJURY

To avoid injury before starting and running the engine, ensure the vehicle is parked on a level surface, parking brake is set, and the wheels are blocked.‪

  1. Attempt to start and run the engine, if the engine starts and runs, no further troubleshooting is required. Shut down the engine.
  2. If the engine fails to start and run, check for a restrictive air filter; refer to "5.12 Restrictive Air Filter" .


EPA07 MBE 900 DDEC VI Troubleshooting Guide - 6SE580