Section 113.3
SPN 3588/FMI 5
This diagnosis for SPN 3588/FMI 5 is typically an open circuit.
Section 113.3.1
Open Circuit Check
Check as follows:
- Disconnect the Ether Start connector at the Ether Injection Relay.
- Turn the ignition ON (key ON, engine OFF).
- Measure the voltage between pin A of the Ether Injection Relay connector and ground.
- If the voltage is greater than 11.5 volts, go to step 4 .
- If the voltage is less than 1.5 volts, repair the open between pin A of the Ether Injection Relay connector and pin 91 of the 120–pin connector. Refer to "113.3.1.1 Verify Repairs" .
- Check the resistance across the Ether Injection Relay connector.
- If the resistance is less than 5 Ω, repair the open between the Ether Injection Relay connector and pin 70 of the 120–pin MCM connector. Refer to "113.3.1.1 Verify Repairs" .
- If the resistance is greater than 15 Ω or open, replace the Ether Injection Relay. Refer to "113.3.1.1 Verify Repairs" .
Section 113.3.1.1
Verify Repairs
Verify repairs as follows:
- Turn ignition OFF.
- Reconnect any electrical connections that were disconnected to perform the diagnosis.
- Clear codes with DDDL 7.0 or latest version.
- Start and bring engine up to operating temperature (over 140°F/60°C).
- Verify operation is satisfactory and no warning lamps illuminate. If warning lamps illuminate, troubleshoot the codes. If assistance is required, call the Detroit Diesel Customer Support Center at 313–592–5800.
| EPA07 Series 60 DDEC VI Troubleshooting Guide - 6SE567 |
| Generated on 10-13-2008 |