Section 67.2
SPN 704/FMI 4
This diagnosis is typically a short to ground.
Section 67.2.1
Short Circuit Check
Check as follows:
- Disconnect the turbo actuator connector.
- Disconnect the 120–pin MCM connector.
- Measure the resistance between pins 1 and 3 of the turbo actuator connector.
- If the resistance is less than 5 Ω, repair the short between pins 35 and 93 of the 120–pin MCM connector. Refer to "67.2.1.1 Verify Repairs" .
- If the resistance is greater than 5 Ω, go to step 4 .
- Measure the resistance between pins 2 and 3 of the turbo actuator connector.
- If the resistance is less than 5 Ω, repair the short between pins 35 and 38 of the 120–pin MCM connector. Refer to "67.2.1.1 Verify Repairs" .
- If the resistance is greater than 5 Ω, go to step 5 .
- Measure the resistance between pin 3 of the turbo actuator connector and ground.
- If the resistance is less than 5 Ω, repair the short between pin 3 of the turbo actuator connector and ground. Refer to "67.2.1.1 Verify Repairs" .
- If the resistance is greater than 5 Ω, go to step 6 .
- Measure the resistance between pin 1 of the turbo actuator connector and ground.
- If the resistance is less than 5 Ω, repair the short between pin 1 of the turbo actuator connector and ground. Refer to "67.2.1.1 Verify Repairs" .
- If the resistance is greater than 5 Ω, refer to "67.2.1.1 Verify Repairs" .
Section 67.2.1.1
Verify Repairs
Verify repairs as follows:
- Turn ignition OFF.
- Reconnect any electrical connections that were disconnected to perform the diagnosis.
- Clear codes with DDDL 7.0 or latest version.
- Start and bring engine up to operating temperature (over 140°F/60°C).
- Verify operation is satisfactory and no warning lamps illuminate. If warning lamps illuminate, troubleshoot the codes. If assistance is required, call the Detroit Diesel Customer Support Center at 313–592–5800.
| EPA07 Series 60 DDEC VI Troubleshooting Guide - 6SE567 |