Section 57.6
SPN 641/FMI 31
This code typically means a turbo actuator internal error code, problem unknown.
Section 57.6.1
Actuator Check
Check as follows:
- Check for multiple codes.
- If 641/9, 641/11, 641/14 or 2795/9 are present, service those faults first.
- If only 641/31 is present, go to the next step.
- Disconnect the turbo actuator.
- Turn the ignition ON (key ON, engine OFF).
- Measure the voltage between pins 1 and 2 of the turbo actuator connector on the engine harness side.
- If the voltage is less than 11.5 volts, go to the next step.
- If the voltage is greater than 11.5 volts, go to step 6 .
- Measure the voltage between pin 1 of the turbo actuator harness connector and ground.
- If the voltage is less than 11.5 volts, repair the cause of low voltage between pin 1 of the turbo actuator harness connector and pin 93 of the MCM 120–pin connector. Refer to "57.6.1.1 Verify Repairs" .
- If the voltage is greater than 11.5 volts, repair the open between pin 2 of the turbo actuator connector on the engine harness side and pin 38 of the MCM 120–pin connector. Refer to "57.6.1.1 Verify Repairs" .
- Turn ignition OFF.
- Disconnect the MCM 120–pin connector.
- Measure the resistance between pin 3 of the turbo actuator harness connector and pin 74 of the MCM 120–pin connector.
- If the resistance is less than 3 Ω, go to the next step.
- If the resistance is greater than 3 Ω, repair the harness between pin 3 of the turbo actuator harness connector and pin 74 of the MCM 120–pin connector. Refer to "57.6.1.1 Verify Repairs" .
- Measure the resistance between pin 4 of the turbo actuator harness connector and pin 75 of the MCM 120–pin connector.
- If the resistance is less than 3 Ω, replace the turbo actuator.
- If the resistance is greater than 3 Ω, repair the harness between pin 4 of the turbo actuator harness connector and pin 75 of the MCM 120–pin connector. Refer to "57.6.1.1 Verify Repairs" .
Section 57.6.1.1
Verify Repairs
Verify repairs as follows:
- Turn ignition OFF.
- Reconnect any electrical connections that were disconnected to perform the diagnosis.
- Clear codes with DDDL 7.0 or latest version.
- Start and bring engine up to operating temperature (over 140°F/60°C).
- Verify operation is satisfactory and no warning lamps illuminate. If warning lamps illuminate, troubleshoot the codes. If assistance is required, call the Detroit Diesel Customer Support Center at 313–592–5800.