Section 11.4
Stopping
The following should be performed for NORMAL stopping:
- Release the load and decrease the "engine speed" in the NEUTRAL position.
- Allow the engine to run at idle with no-load for a few minutes, then turn the key switch to the OFF position.
The following should be performed for NORMAL stopping:
- Fill fuel tank. A full tank will minimize condensation.
- Check coolant level. Add coolant, if necessary, to bring it to the proper level.
- Check the oil level in the crankcase. Add oil, if necessary, to bring it to the proper level on the dipstick.
- Make a visual check for external leaks in the fuel, lubricating and cooling systems.
Section 11.4.1
Emergency Stopping
To stop the engine, turn the key to the OFF position.