Section 93.1
SPN 1636 /FMI 2
This diagnostic condition is typically erratic data.
Section 93.1.1
Erratic Data Source Check
Check as follows:
Note: When diagnosing rationality erratic data faults always refer to any SIBs first for any known issues.
- Check the air intake, CAC EGR system integrity and the intake throttle system integrity.
- Connect the diagnostic tool.
- Monitor the engine RPM, engine coolant temperature, intake manifold temperature, EGR temperature, EGR PW and EGR Delta P counts.
- With the engine at idle and the coolant temperature above 160°, are the EGR PW less than 7% and the EGR Delta P counts less than 135 (NO EGR FLOW)? Is the intake manifold temperature within __ ° of the EGR temperature?
- If yes, go to step 7 .
- If no, go to step 5 .
- Disconnect the Intake Manifold Pressure/Temp Sensor and the 120–pin MCM connector.
- Bridge pins 1 and 2 of the Intake Manifold Pressure/Temp Sensor, measure the resistance at pins 52 and 106 of the 120–pin MCM connector.
- If the resistance is greater than 3 Ω, repair the harness. Refer to "93.1.1.1 Verify Repairs" .
- If the resistance is less than 3 Ω, replace the sensor. Refer to "93.1.1.1 Verify Repairs" .
- With the engine running at 1500 rpm and coolant temperature above 160°, command EGR PW to 50% (EGR Delta P counts will also rise because of EGR flow). Is the intake manifold temperature within __° of the EGR temperature?
- If yes, contact the Detroit Diesel Customer Support Center (313–592–5800).
- If no, replace the sensor. Refer to "93.1.1.1 Verify Repairs" .
Section 93.1.1.1
Verify Repairs
Verify repairs as follows:
- Turn ignition OFF.
- Reconnect any electrical connections that were disconnected to perform the diagnosis.
- Clear codes with DDDL 7.0 or latest version.
- Start and bring engine up to operating temperature (over 140°F/60°C).
- Verify operation is satisfactory and no warning lamps illuminate. If warning lamps illuminate, troubleshoot the codes. If assistance is required, call the Detroit Diesel Customer Support Center at 313–592–5800.
| EPA07 MBE 900 DDEC VI Troubleshooting Guide - 6SE580 |