Section 27.2
SPN 100/FMI 2
The diagnosis for this code is typically erratic data from the Engine Oil Pressure Switch/Sensor.
Section 27.2.1
Erratic Data From the Engine Oil Pressure Switch/Sensor
Check as follows:
- With the engine shut down, all oil drained into the oil pan, and the vehicle on a level surface, check the oil level.
- If the oil level is not within the “normal” operating range on the dipstick, add the recommended oil to bring it to the proper level. Refer to "27.2.1.1 Verify Repairs" .
- If the oil level is within the “normal” operating range on the dipstick, go to step 2 .
- Check for additional active fault codes.
- If fault code 100/3 is active in addition to code 100/2, refer to "27.4.1 Open Short to Ground Check" .
- If fault code 100/4 is active in addition to code 100/2, refer to "27.3.1 Open Short to Power Check" .
- If only fault code 100/2 is active, check and clean switch contacts (remove any corrosion). Refer to "27.2.1.1 Verify Repairs" .
Section 27.2.1.1
Verify Repairs
Verify repairs as follows:
- Turn ignition OFF.
- Reconnect any electrical connections that were disconnected to perform the diagnosis.
- Clear codes with DDDL 7.0 or latest version.
- Start and bring engine up to operating temperature (over 140°F/60°C).
- Verify operation is satisfactory and no warning lamps illuminate. If warning lamps illuminate, troubleshoot the codes. If assistance is required, call the Detroit Diesel Customer Support Center at 313–592–5800.