Section 117.4
SPN 3563/FMI 20
The following procedures will troubleshoot SPN 3563/FMI 20, Intake Manifold Pressure Plausibility (Low Box).
Section 117.4.1
Intake Manifold Pressure Plausibility
Check as follows:
- Using DDDL perform the Air Mass Adaptation (AMA) service routine.
- After the AMA completes, clear all faults.
- Start the engine and idle for three minutes.
- Is SPN 3563/FMI 20 active?
- Yes, go to step 5 .
- No, testing is complete, release the vehicle.
- Turn the engine OFF.
- Turn the ignition ON (Key ON, engine OFF).
- Monitor Compressor Inlet Pressure, Barometric Pressure and Inlet Manifold Pressure.
- Are all of the pressures within 0.5 PSI of each other?
- Is Barometric Pressure within 0.5 PSI of Inlet Manifold Pressure?
- Yes, replace the Compressor Inlet Pressure Sensor.
- No, go to step 10 .
- Connect a known good Inlet Manifold Pressure Sensor.
- Is Barometric Pressure within 0.5 PSI of Inlet Manifold Pressure?
- Yes, replace the Inlet Manifold Pressure Sensor.
- No, replace the MCM.
- Start the engine.
- At Idle, compare Compressor Inlet Pressure, Barometric Pressure and Inlet Manifold Pressure.
- Are all of the pressures within 0.8 PSI of each other?
- Is Barometric Pressure within 0.8 PSI of Inlet Manifold Pressure?
- Yes, replace the Compressor Inlet Pressure Sensor.
- No, go to step 16 .
- Connect a known good Inlet Manifold Pressure Sensor.
- Is Barometric Pressure within 0.8 PSI of Inlet Manifold Pressure?
- Yes, replace the Inlet Manifold Pressure Sensor.
- No, replace the MCM.
- Perform CAC inspection and leak test. Refer to OEM literature for procedure.
- If inspection and/or leak test fail, repair as necessary.
- If CAC inspection passes, obtain DDDL log file of failure and contact the Detroit Diesel Customer Support Center at 313–592–5800.
Section 117.4.1.1
Verify Repairs
Verify repairs as follows:
- Turn ignition OFF.
- Reconnect any electrical connections that were disconnected to perform the diagnosis.
- Clear codes with DDDL 7.0 or latest version.
- Start and bring engine up to operating temperature (over 140°F/60°C).
- Verify operation is satisfactory and no warning lamps illuminate. If warning lamps illuminate, troubleshoot the codes. If assistance is required, call the Detroit Diesel Customer Support Center at 313–592–5800.