Section 8.5
SPN 164/FMI 4
SPN 164/FMI 4 indicates a Rail Pressure Governor Sensor Circuit Failed Low (short to ground).

Check as follows:
- Check for multiple codes.
- If faults for the Intake Manifold Pressure/Temperature Sensor are active at the same time, repair the circuits between pin 58 or pin 102 of the MCM 120-pin Connector and pin 2 or pin 4 of the Intake Manifold Pressure/Temperature Sensor. Refer to "8.5.1 Verify Repairs" .
- If only fault 164/4 is active, go to the next step.
- Disconnect the Rail Pressure Governor Sensor.
- Disconnect the MCM 120-pin connector.
- Measure the resistance of pin 1 of the Rail Pressure Governor Sensor connector and ground.
- If resistance is less than 5 Ω, repair short between pin 102 of the 120-pin MCM connector and ground. Refer to "8.5.1 Verify Repairs" .
- If resistance is greater than 5 Ω, go to the next step.
- Measure the resistance between pin 2 of the Rail Pressure Governor Sensor harness connector and ground.
- If resistance is less than 5 Ω, repair the short circuit between pin 2 of the Rail Pressure Governor Sensor harness connector and ground. Refer to "8.5.1 Verify Repairs" .
- If resistance is greater than 5 Ω, go to the next step.
- Measure the resistance between pin 3 of the Rail Pressure Governor Sensor harness connector and ground.
- If resistance is less than 5 Ω, repair the short circuit between pin 3 of the Rail Pressure Governor Sensor harness connector and ground. Refer to "8.5.1 Verify Repairs" .
- If resistance is greater than 5 Ω, review steps 4 through 6 . If the results are the same, contact Detroit Diesel Customer Support Center (313-592-5800).
Section 8.5.1
Verify Repairs
Verify repairs as follows:
- Turn ignition OFF.
- Reconnect any electrical connections that were disconnected to perform the diagnosis.
- Clear codes with DDDL 7.0 or latest version.

ENGINE EXHAUST
To avoid injury from inhaling engine exhaust, always operate the engine in a well-ventilated area. Engine exhaust is toxic.
- Start and bring engine up to operating temperature (over 140°F/60°C).
- Verify operation is satisfactory and no warning lamps illuminate. If warning lamps illuminate, troubleshoot the codes. If assistance is required, call the Detroit Diesel Customer Support Center at 313–592–5800.