Section 113.1
SPN 3511/FMI 3
This diagnosis typically means the 3 V sensor supply bank 1 circuit failed high.
This fault indicates that the MCM detects a short to power (voltage > 3.2) on any of the MCM pins listed in Table "MCM Pins for Short to Power Check" .
|
Component |
MCM Pin |
|
DOC Outlet Temperature Sensor |
29 |
|
DOC Inlet Temperature Sensor, DOC Outlet Temperature Sensor, DPF Outlet Temperature Sensor |
88 |
|
DOC Inlet Temperature Sensor |
89 |
|
DPF Outlet Temperature Sensor |
115 |
Table 1. MCM Pins for Short to Power Check
Inspect the harness and repair as necessary. Refer to "113.1.1 Verify Repairs" .
Section 113.1.1
Verify Repairs
Verify repairs as follows:
- Turn ignition OFF.
- Reconnect any electrical connections that were disconnected to perform the diagnosis.
- Clear codes with DDDL 7.0 or latest version.
- Start and bring engine up to operating temperature (over 140°F/60°C).
- Verify operation is satisfactory and no warning lamps illuminate. If warning lamps illuminate, troubleshoot the codes. If assistance is required, call the Detroit Diesel Customer Support Center at 313–592–5800.
| EPA07 DD15 Troubleshooting Guide - DDC-SVC-MAN-0029 |
| Generated on 10-13-2008 |
SPN 520364
FMI 3