Section 28.2
SPN 111/FMI 3
This condition is typically a circuit failed high.

Check as follows:
- Check for multiple codes.
- If other faults are active in addition to fault 111/3, troubleshoot the other faults first.
- If only fault 111/3 is active, go to the next step.
- Disconnect the ECL Sensor.
- Measure the resistance between pin 1 and 2 of the ECL Sensor.
- If the resistance is greater than 600 kΩ (submerged) or open, replace ECL sensor. Refer to "28.2.1 Verify Repairs" .
- If the resistance is less than 600 kΩ, go to the next step.
- Turn the ignition ON (key On, engine OFF).
- Measure the voltage between pins 1 and 2 of the ECL Sensor harness connector.
- If the voltage is greater than 2.75 volts, go to step 7 .
- If the voltage is less than 2.75 volts, go to the next step.
- Measure the voltage between pin 1 of the ECL Sensor harness connector and ground.
- If the voltage is greater than 2.75 volts, repair the open between pin 2 of the CPC #3 connector and the ECL Sensor harness. Refer to "28.2.1 Verify Repairs" .
- If the voltage is less than 2.75 volts, repair the open between pin 11 of the CPC #3 connector and the ECL Sensor harness. Refer to "28.2.1 Verify Repairs" .
- Disconnect the CPC #3 connector.
- Measure the resistance between pins 1 and 2 of the ECL Sensor harness connector.
- If the resistance is less than 5 Ω, repair the short between the ECL Sensor harness connector pins 1 and 2 and pins 2 and 11 of the CPC #3 connector. Refer to "28.2.1 Verify Repairs" .
- If the resistance is greater than 5 Ω, review the steps already taken. If the results are the same, call the Detroit Diesel Customer Support Center (313–592–5800).
Section 28.2.1
Verify Repairs
Verify repairs as follows:
- Turn ignition OFF.
- Reconnect any electrical connections that were disconnected to perform the diagnosis.
- Clear codes with DDDL 7.0 or latest version.

ENGINE EXHAUST
To avoid injury from inhaling engine exhaust, always operate the engine in a well-ventilated area. Engine exhaust is toxic.
- Start and bring engine up to operating temperature (over 140°F/60°C).
- Verify operation is satisfactory and no warning lamps illuminate. If warning lamps illuminate, troubleshoot the codes. If assistance is required, call the Detroit Diesel Customer Support Center at 313–592–5800.
| EPA07 DD15 Troubleshooting Guide - DDC-SVC-MAN-0029 |
| Generated on 10-13-2008 |